C-D364 service code when copying/printing. Options
awais
#1 Posted : Wednesday, March 24, 2010 9:45:52 AM
Rank: Administration


Joined: 12/12/2009
Posts: 16
Location: Lahore
CAUSE:A NVRAM Data error.

SOLUTION: Restore NVRAM Data. When NVRAM data error is detected, restoring the backup data from Flash ROM on MFPC board is possible with the following procedure:

1. Press [Stop] > [0] > [7] > [1] > [3] > [9].
  • Will be shown on the control panel.
    2.Press the
  • on the control panel.

    Note : This CD3XX error code may appear again and require the NVRAM Data restore procedure to be performed several times before clearing the error code(s) completely. By pressing
  • , the data restore can be initiated. Restoring data takes a very short time.

    3.When restore is finished, the control panel displays the message to power OFF the Main SW.
    4. Power switch OFF/ON.
    5.If restore failed, the trouble code will be shown again. If any trouble is detected, bring
  • onto the control panel.The actual restore is only possible when a NVRAM data error is detected.